gf8340d4010h

Additional fan, component description

유형 gf · 주제 83.40 · 버전 0100 · 2009-04-21

적용 대상: MODEL 906.111 /113 /131 /133 /135 /153 /155 /211 /213 /231 /233 /235 /253 /255 /611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 except CODE (HH9) Regulated air conditioning (Tempmatic)

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 83 에어컨 › 83.40 자동에어컨 — 시리즈 906 (모델 111, 113, 131, 133, 135, 153, 155, 211, 213, 231, 233, 235, 253, 255, 611, 613, 631, 633, 635, 637, 653, 655, 657, 711, 713, 731, 733, 735)

GF83.40-D-4010H

Additional fan, component description

12.5.06

MODEL 906.111 /113 /131 /133 /135 /153 /155 /211 /213 /231 /233 /235 /253 /255 /611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 except CODE (HH9) Regulated air conditioning (Tempmatic)

Additional fan, component description

D83.40-1110-06

M4/13 Air conditioner 1 additional fan

M4/14 Air conditioner 2 additional fan

Location

The two air conditioner additional fans are located at the front between the front condenser and the front bumper at the radiator module.

Task

The two air conditioner additional fans ensure that the front condenser and the radiator are cooled down when the vehicle is stationary or driving.

Function

Function requirement: "circuit 15 ON".

Depending on how it is actuated by the AAC [KLA] control and operating unit (S98), the additional fan relay (K9) switches the two air conditioner additional fans into a series or parallel connection. In the event of the following coolant temperatures or refrigerant pressures, the two air conditioner additional fans are switched on or off.

Temperature or pressure

Stage 1 (series connection) ON

Stage 1 (series connection) OFF

Stage 2 (parallel connection) ON

Stage 2 (parallel connection) OFF

Coolant temperature

107°C

102°C

115°C

110°C

Refrigerant pressure

16 bar

12 bar

20 bar

16 bar

As soon as stage 2 is connected, it is no longer actuated by the additional fan relay (holding relay). When switching back to
stage 1, stage 2 is switched off first and after 3 s (parameterizable) stage 1 is switched on again.

Stage 2 is not switched on directly. Stage 1 is switched on for at least 3 s at first.

During the starting procedure, the two air conditioner additional fans are not switched on.