gf8340d2191h

Desiccant cartridge, component description

유형 gf · 주제 83.40 · 버전 0100 · 2006-05-30

적용 대상: MODEL 906.111 /113 /131 /133 /135 /153 /155 /211 /213 /231 /233 /235 /253 /255 /611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 except CODE (HH9) Regulated air conditioning (Tempmatic)

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 83 에어컨 › 83.40 자동에어컨 — 시리즈 906 (모델 111, 113, 131, 133, 135, 153, 155, 211, 213, 231, 233, 235, 253, 255, 611, 613, 631, 633, 635, 637, 653, 655, 657, 711, 713, 731, 733, 735)

GF83.40-D-2191H

Desiccant cartridge, component description

12.5.06

MODEL 906.111 /113 /131 /133 /135 /153 /155 /211 /213 /231 /233 /235 /253 /255 /611 /613 /631 /633 /635 /637 /653 /655 /657 /711 /713 /731 /733 /735 except CODE (HH9) Regulated air conditioning (Tempmatic)

Desiccant cartridge, component description

D83.40-1103-08

31 Front desiccant cartridge

32 Front condenser

Location

The front desiccant cartridge is located on the right side next to the radiator and the front condenser.

Task

Dirt and moisture are eliminated from the liquid refrigerant in the front desiccant cartridge. At the same time, the front desiccant cartridge is used as a reservoir to supply the air conditioning with a sufficient amount of refrigerant.