gf8320w3101a

Blower rotary switch, location/task/function

유형 gf · 주제 83.20 · 버전 0103 · 2004-10-13

적용 대상: MODEL 950, 952, 953, 954 with BODY 942.899

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 83 에어컨 › 83.20 히터 — 시리즈 942 (모델 899) · 시리즈 950 · 시리즈 952 · 시리즈 953 · 시리즈 954

GF83.20-W-3101A

Blower rotary switch, location/task/function

24.4.96

MODEL 950, 952, 953, 954 with BODY 942.899

Blower rotary switch, location/task/function

W83.20-0005-09

1 Blower level 1

2 Blower level 2

3 Blower level 3

4 Blower level 4

5 Fresh air blower setting

6 Recirculated air blower setting

7 Radial blower

8 DC gear motor for fresh air/air recirculation flaps

Task

Switching of 4 blower stages in fresh air and recirculated air range.

Function

Fresh air/recirculated air switchover realized by 2-pin changeover of voltage supply of DC gear motor (8). There are 2 blower "OFF" positions

1. Blower setting, fresh air (5)

2. Blower setting, recirculated air (6)

The blower switch has 10 positions. The switch rotation angle is 180°.

The latching angle is 20° between the individual positions.

The rotary switch latching gate is integrated into the lighting prism; latching ensues by way of an axial-force free plastic two-phase spring.

Location

The blower switch is integrated into the operating unit.

Resistance control for blower motor, design/task/function/location

GF83.20-W-3108A

Digital blower regulator for blower motor, design/task/function/location

GF83.20-W-3109A

참조 문서