az8220p000102ca

Connecting wiring harness

유형 az · 주제 82.20 · 버전 0100 · 1999-11-10

적용 대상: MODEL 210.### 1# as of 1.3.97 up to 30.6.99

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 82 전기적 장치, 구조 › 82.20 실내 조명 — 시리즈 210

EinPAS 30 조명 시스템 › 30.20 내부 조명 › 30.20.3 추가 장착/개조 — 시리즈 210

AZ82.20-P-0001-02CA

Connecting wiring harness

Model 210 from 1.3.97 to 30.6.99

Connecting wiring harness

P82.20-2146-06

Wiring harness connection schematic

Illuminated entrance trim panel

1 Illuminated entrance trim panel wiring harness

7 Converter

10 2-pin connector for converter

11 2-pin connector for illuminated strip

F4 Rear fuse box

br/bl Brown/blue lead for right door contact

br/gr Brown/gray lead for left door contact

rt Red lead, circuit 30

Connecting wiring harness

P82.20-2156-01

1 Insert red (rt) lead into free chamber for fuse 3 from rear fuse box (F4).

2 Route wiring harness (1) to right cable duct.

3 Route long tieout (1a) with brown/gray lead for left door contact below rear seat (see dotted line) to left B-pillar base and fasten.

Fasten wiring harness tieout (1a) below rear seat with felt strips in bead.

Connecting wiring harness

P82.20-2157-01

4 Expose brown/gray (br/gr) lead from wiring harness from left door contact and check.

5 Connect brown/gray (br/gr) lead from wiring harness (1) to brown/gray (br/gr) lead from wiring harness from left door contact and insulate (see magnified section).

Connecting wiring harness

P82.20-2158-01

6 Route short tieout from wiring harness with brown/blue (br/bl) lead in right cable duct up to B-pillar.

7 Expose connection lead for right door contact and tie out brown/blue (br/bl) lead.

8 Solder brown/blue lead (br/bl) from wiring harness to brown/blue (br/bl) lead from right door contact and insulate (see magnified section).

Connecting wiring harness

P82.20-2166-01

9 Route converter (7), 2-pin plug connector (10) and 2-pin connector for illuminated strip (11) forward to the associated cable duct and position.

2-pin connector for illuminated strip (11) can be connected to illuminated strip later.