1 | Fuel line |
2 | Coolant hoses |
3 | Screw |
4 | Bolts |
5 | Electrical connectors |
A6 | STH heater unit |
M46/1 | STH fuel metering pump |
S83.70-4509-06
Danger ! | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Danger ! | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Danger ! | Risk of explosion caused by fuel vapors igniting, risk of poisoning caused by inhaling combustible gases and risk of injury caused by burns during and after operation of heater unit | Do not operate stationary heater, auxiliary heater or engine with heater booster in closed rooms or when refueling. Allow heater unit to cool down after operation and wear protective gloves. | |
| Remove/install | ||
1 | Drain coolant |
| |
2 | Remove fuel line (1) from STH heater unit (A6) | Collect escaping fuel. | |
3 | Close off the fuel line (1) with the stop plugs | Record plug | |
4 | Loosen clamps on coolant hoses (2) | ||
5 | Remove coolant hoses (2) from STH heater unit (A6) | Collect coolant which flows out. | |
6 | Unscrew bolt (3) | Bracket to floor assembly | |
7 | Loosen bolts (4); do not remove completely | Secure STH heater unit (A6) to prevent it from falling down. | |
Bracket to floor assembly | |||
8 | Disconnect electrical connections (5) | ||
9 | Disconnect electrical connector on STH fuel metering pump (M46/1) | ||
10 | Remove STH heater unit (A6) together with the bracket | ||
11 | Install in the reverse order | ||
| Check | ||
12 | Perform test run of STH heater unit (A6) and check fuel system on STH heater unit (A6) for leaktightness |
129 589 00 91 00
Record plug
참조 문서
- ar2000s1140s
- as2000z000101a 뜨거운 냉각수 분출 시 입은 화상에 의한 피부와 안구의 상해 위험 냉각수의 음용으로 인한 중독 위험
- as4700z000101a 인화에 의한 폭발 위험, 연료의 흡입 및 음용에 의한 중독 위험, 연료의 피부 및 안구 접촉에 의한 상해 위험
- as8370z000201a 연료 증발가스에 의한 폭발 위험, 연소가스 흡입으로 인한 중독 위험 및 히터 작동 시 또는 작동 후 화상 위험