AR83.70-D-5653B | Removing and installing fuel strainer in intake connection of fuel metering pump | 4.11.96 |
MODEL 901.36# /37# /46#, 902.36# /37# /46# /47#, 903.36# /37# /46# /47#, 904.36# /46# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation D3L-C
D83.70-0036-06
1 Fuel line
2 Hose clamp
3 Fuel metering pump
4 Union nut
5 Fuel strainer filter
| Removal, installation | ||
Danger! | Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation | Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves. | |
Danger! | Fuel vapors present an explosion hazard. Fuel vapors are toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury. | Fire, open lights and smoking prohibited. Wear protective clothing when handling fuel. | |
1 | Remove heater | Models 901.36/37/46, 902.36/37/46/47, 903.36/37/46/47, 904.36/46 left-hand steering | |
Models 901.36/37/46, 902.36/37/46/47, 903.36/37/46/47, 904.36/46 right-hand steering | |||
2 | Loosen hose clamp (2) | ||
3 | Pull off fuel line (1) | Catch fuel running out. | |
4 | Unscrew union nut (4) | To loosen union nut hold fuel metering pump. | |
5 | Remove fuel strainer filter (5) | ||
6 | Install in opposite order |
참조 문서
- ar8370d5302d
- ar8370d5302e
- as4700z000101a 인화에 의한 폭발 위험, 연료의 흡입 및 음용에 의한 중독 위험, 연료의 피부 및 안구 접촉에 의한 상해 위험
- as8370z000201a 연료 증발가스에 의한 폭발 위험, 연소가스 흡입으로 인한 중독 위험 및 히터 작동 시 또는 작동 후 화상 위험