ar8370d5652c

Removing and installing fuel metering pump

유형 ar · 주제 83.70 · 버전 0104 · 1998-07-31

적용 대상: MODEL 901.06#, 902.06# /07#, 903.06# /07#, 904.06# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater Heater designation B3L-C

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 83 에어컨 › 83.70 보조히터, 추가히터, 추가히터 — 시리즈 901 (모델 06*) · 시리즈 902 (모델 06*, 07*) · 시리즈 903 (모델 06*, 07*) · 시리즈 904 (모델 06*)

EinPAS 39 히터/환기/에어컨 › 39.25 독립식 히터/보조 히터 › 39.25.46 펌프/탱크 — 시리즈 901 (모델 06*) · 시리즈 902 (모델 06*, 07*) · 시리즈 903 (모델 06*, 07*) · 시리즈 904 (모델 06*)

AR83.70-D-5652C

Removing and installing fuel metering pump

4.11.96

MODEL 901.06#, 902.06# /07#, 903.06# /07#, 904.06# ## up to 753730 up to 31.10.97 with CODE (H11) Hot air auxiliary heater
Heater designation B3L-C

Removing and installing fuel metering pump

D83.70-0060-11

1 Electrical connector
2 Electrical connector
3 Fuel line to heater
4 Hose clamp
5 Fuel metering pump
6 Hose clamp
7 Fuel line to fuel tank
8 Washer
9 Hex. nut
10 Holder

Removal, installation

Location of fuel metering pump changed to avoid formation of vapor bubbles

If the fuel metering pump is fastened to the bottom of the heater, convert by mounting on front of heater.

BT83.70-D-0001-01A

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation

Do not start up or operate stationary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

Danger!

Fuel vapors present an explosion hazard. Fuel vapors are toxic when inhaled or absorbed. Contact with fuel can cause eye and skin injury.

Fire, open lights and smoking prohibited.
Fill and store fuel only in containers intended for this purpose and marked accordingly.

Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

1

Loosen hose clamp (4) and pull off fuel
line (3)

Catch fuel running out.

2

Loosen hose clamp (6) and pull off fuel
line (7)

Catch fuel running out.

3

Disconnect electrical connectors (1, 2)

4

Remove fuel metering pump (5)

5

Install in opposite order

참조 문서