Shown with upper engine cover removed |
3 | Left air filter housing |
4 | Screw |
5 | High pressure pipe |
S83.30-A036-76
Shown with engine removed |
5 | High pressure pipe |
S83.30-A029-82
Caution | Risk of injury caused by scraping or cutting body parts on sharp vehicle parts | Always wear protective gloves when working on or near sharp and non-deburred vehicle parts. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Topical note | Notes on avoiding damage through contamination and foreign objects | ||
Notes on handling refrigerant R134a | |||
| Remove/install | ||
1 | Discharge air conditioning system. | ||
2 | Remove left front wheel. | ||
3 | Remove left fender liner. | ||
4 | Remove high-pressure line (5) from refrigerant compressor. | ||
| Compressor oils (specification 362.1) | ||
| |||
Installation: Replace sealing ring of high-pressure line (5) and moisten with compressor oil. | |||
Bolt, refrigerant line to refrigerant compressor | |||
Assembly tool | |||
Record plug | |||
5 | Remove left air filter housing (3). | ||
6 | Unscrew screw (4) and remove high-pressure line (5). | ||
| Compressor oils (specification 362.1) | ||
| |||
Installation: Replace sealing ring of high-pressure line (5) and moisten with compressor oil. | |||
Screw, refrigerant line to refrigerant line front connecting point | |||
Record plug | |||
Assembly tool | |||
7 | Install in the reverse order |
000 589 93 63 00
Assembly tool
129 589 00 91 00
Record plug
참조 문서
- ah0000p500001a 불순물 및 이물질에 의한 손상 방지 지침
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar0910s1150ps
- ar4010s1100p
- ar8330s1760p
- ar8810s1301p
- as0000z001701a 모서리가 날카로운 차량 부품에서 절단상과 찰과상으로 인한 상해 위험
- as8300z000601a R134a로 채워진 에어컨의 과열된 냉매 증기를 흡입할 경우 발생하는 중독 위험 액체형 냉매 R134a가 피부와 눈에 접촉하는 경우 및 압력이 가해지는 부품에서 작업하는 경우 발생하는
- bb0040p036201a 컴프레서 오일(사양 362.1)