1 | Desiccant cartridge |
2 | Refrigerant condenser |
3 | Screw |
4 | O-rings |
S83.30-A005-82
Shown with engine 780.702 |
3 | Screw |
S83.30-A073-81
Danger | Risk of fire due to ignition of R1234yf refrigerant on hot components. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with escaped R1234yf refrigerant and when working on pressurized parts. Risk of explosion due to formation of ignitable refrigerant/air mixtures | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated. | |
Warning | Risk of poisoning caused by inhaling overheated refrigerant vapors from an air conditioning system containing R134a. Risk of injury to skin and eyes caused by contact with liquid R134a refrigerant and when working on pressurized parts | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated rooms. Carry out repair work on the air conditioning system circuit only after the system has been evacuated.Model 447 with engine 780.701 | |
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R1234yf | |||
Notes on handling refrigerant R134a | Model 447 with engine 780.701 | ||
| Remove/install | ||
1.1 | Empty refrigerant circuit. | Model 447 with engine 780.702 | |
1.2 | Remove refrigerant condenser (2). | Model 447 with engine 780.701 | |
2 | Remove bottom engine compartment paneling. |
| |
3 | Remove bolt (3) . | Model 447 with engine 780.702 | |
Bolt, receiver drier to refrigerant condenser | |||
4 | Lower vehicle. | Model 447 with engine 780.702 | |
5 | Remove receiver drier (1) from refrigerant condenser (2). | ||
| Compressor oils (specification 362.1) | ||
Plug openings. | |||
Installation: Ensure that receiver drier (1) is seated correctly on condenser (2). If the packaging is damaged or the stop plugs are missing, do not install the new receiver drier (1). | |||
Assembly tool | |||
Record plug | |||
6 | Install in the reverse order. |
000 589 93 63 00
Assembly tool
129 589 00 91 00
Record plug
참조 문서
- ah8330n000301a 냉매 R134a 취급 관련 지침
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ah8330p000302a 냉매 R1234yf 처리 관련 지침
- ar6120s1105e
- ar6120s1105e
- ar8330s0013f
- ar8330s1760ef
- as8300z000601a R134a로 채워진 에어컨의 과열된 냉매 증기를 흡입할 경우 발생하는 중독 위험 액체형 냉매 R134a가 피부와 눈에 접촉하는 경우 및 압력이 가해지는 부품에서 작업하는 경우 발생하는
- as8300z000701a 고온 부품에서 냉매 R1234yf에 불이 붙을 경우 발생하는 화재 위험 과열된 냉매 증기의 흡입으로 인한 중독 위험 방출된 냉매 R1234yf가 피부와 눈에 접촉하는 경우 및 압력이 가해지는
- bb0040p036201a 컴프레서 오일(사양 362.1)