D83.30-A031-79
Shown with heat exchanger removed |
1 | Refrigerant condenser | 4 | Coolant hose | 7 | Refrigerant line | ||
2 | Desiccant cartridge | 6 | Refrigerant line | 9 | Coolant hose | ||
3 | Pressure and temperature sensor |
D83.30-A032-79
Shown with heat exchanger removed |
1 | Refrigerant condenser | 3 | Pressure and temperature sensor | 11 | Electrical connector | ||
2 | Desiccant cartridge | 10 | Nuts |
Danger | Risk of death when working on component parts and systems with U >= 30 V alternating voltage (AC) or U >= 60 V direct voltage (DC) | Do not touch damaged or defective live component parts and lines or non-insulated electrical connections and lines. | |
Warning | Risk of injury to skin and eyes suffering scalding from contact with hot coolantspray. Risk of poisoning from swallowing coolant. | Do not open cooling system unless coolant temperature is below 90 °C. Open cap slowly and release the pressure. Do not pour coolant into beverage containers. | |
Topical note | General information on vehicles with high-voltage on-board electrical system and/or lithium-ion battery and/or gaseous-fuel drive system as well as personal protective equipment | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
| Remove/install | ||
1 | Remove heat exchanger. | ||
2 | Remove coolant hoses (4, 9) from refrigerant condenser (1). | ||
Collect escaping coolant in a suitable container. Seal connections. | |||
Set of protective covers | |||
3 | Remove refrigerant line (7) from refrigerant condenser (1). | ||
Seal refrigerant line (7). | |||
Record plug | |||
4 | Remove refrigerant line (6) from refrigerant condenser (1). | ||
Seal refrigerant line (6). | |||
Record plug | |||
5 | Disconnect electrical connector (11) at pressure and temperature sensor (3). | ||
6 | Remove nuts (10) from refrigerant condenser (1). | ||
Topical note | Notes on self-locking nuts and bolts | ||
Nut, refrigerant condenser for high-voltage battery cooling system to supporting frame | |||
7 | Remove refrigerant condenser (1) with attached receiver drier (2) and installed pressure and temperature sensor (3). | ||
8 | Install in the reverse order. |
001 589 01 91 00
Set of protective covers
129 589 00 91 00
Record plug
참조 문서
- ah0000n000101a 자가 잠금식 볼트와 너트 관련 지침
- ah0000z030001a 고전압 차량 전원 시스템 및/또는 리튬 이온 배터리 및/또는 가스 구동 시스템 장착 차량과 개인 보호 장비에 관한 일반 지침
- ah8330n000401a 에어컨이 파손되었거나 누출이 있을 경우의 조치
- ah8330n000501a 정비 작업 시 에어컨의 회로와 부품들을 습기로부터 보호하십시오.
- ar0850d0302te
- ar0850p001801eq 냉각수 호스 커플링 열기, 닫기
- ar8330d7840te
- ar8330d7841te
- as0000z003501a U >= 30V 교류(AC) 또는 U >= 60V 직류(DC)를 사용하는 부품 및 시스템 작업 시 생명 위험
- as2000z000101a 뜨거운 냉각수 분출 시 입은 화상에 의한 피부와 안구의 상해 위험 냉각수의 음용으로 인한 중독 위험