Hinged doors
Number | Designation | Model | Model | Model | ||
BA72.15-N-1013-01C | Bolt, striker bolt to B-pillar | Nm | 20 | 20 | 20 | |
D72.15-1121-01
1 Loosen bolts (2).
2 Adjust installation depth by horizontally moving lock striker.
Adjust door with a protrusion of 0.2 mm to max. 1 mm. It is necessary to maintain the slight protrusion at the rear, so that the door does not cant on the B-pillar in the event of a crash. Rotary tumbler should engage in the center of the locking eye.
3 Tighten bolts (2). Observe specified tightening torque.