P68.10-3422-09
1 Door seal
2 Cover
3 Air pipe
4 Side air outlet
P68.10-3423-11
4 Side air outlet
5 Electrical connector
E10/2 Left air outlet illumination
E10/3 Right air outlet illumination
| Remove/Install | ||
1 | Remove door seal (1) in working area | Left or right | |
2 | Unscrew cover (2) (arrows B) | Long wedge | |
3 | Remove cover (2) downward | Installation: Observe guide lug in area A. | |
4 | Pull out air pipe (3) | Installation: Ensure that air pipe (3) is seated correctly. | |
5 | Unclip side air outlet (4) through air outlet opening with pulling hook | Unclip downward first. | |
Slide pulling hook vertically through clip (arrow C), then turn to left or right and pull. | |||
Pulling hook | |||
6 | Remove side air outlet (4) from instrument panel until left air outlet illumination (E10/2) or right air outlet illumination (E10/3) is accessible | ||
7 | Unclip left air outlet illumination (E10/2) or right air outlet illumination (E10/3) from side air outlet (4) | Installation: Ensure that left air outlet illumination (E10/2) or right air outlet illumination (E10/3) is positioned correctly. | |
8 | Disconnect electrical connector from left air outlet illumination (E10/2) or right air outlet illumination (E10/3) | ||
9 | Remove side air outlet (4) | ||
10 | Install in the reverse order |
140 589 02 33 00
Pulling hook
Long wedge
115 589 03 59 00