1 | Bracket |
A | Range |
D61.10-0149-06
| Remove | ||
Warning | Risk of injury caused by performing testing or repair work on airbag or emergency tensioning retractor units. | Store airbag units with deployment side facing up; do not expose to temperatures greater than 100 °C. When working on these units, disconnect the power supply. | |
Topical note | Notes on performing repair, body work and welding on vehicles with airbags and RTE units | ||
Topical note | General information on body repair | ||
1 | Remove hydraulic unit |
| |
Model 901.6, 902.6, 903.6, 904.6, 905.6, 690.6 | |||
2 | Remove detachable parts in repair area | ||
3 | Cover all detachable parts that remain in the repair area | ||
4 | Expose and grind down weld seams in the area A | ||
5 | Remove bracket (1) | Zinc dust paint suitable for spot welding | |
Zinc dust paint suitable for spot welding | |||
| Install | ||
6 | Grind off both sides of the bracket (1) in the marked areas and coat it with zinc dust paint | Zinc dust paint suitable for spot welding | |
Zinc dust paint suitable for spot welding | |||
7 | Position mount (1) according to dimensions specified in drawing and align | ||
Danger | The high voltage used for electric welding presents a lethal hazard. Risk of explosion from welding in areas close to highly inflammable materials. Risk of injury from weld splatter and UV-light when welding. Risk of poisoning from inhaling welding gases | Use insulating mats. Wear protective clothing, safety glasses and a protective mask. Remove highly inflammable materials from the hazard area. Use air extraction system. | |
8 | Weld the bracket (1) to the body ( ) | ||
Topical note | Measures for preventing damage to vehicles or components when performing electric welding work | ||
General notes on welding | |||
9 | Vacuum out hollow cavities | | |
10 | Clean areas repaired and priming with MB primer filler | ||
11 | Supplement standard underfloor protection with MB permanent underbody sealant | ||
12 | Paint repair area adjacent surfaces | ||
13 | Install hydraulic unit |
| |
Model 901.6, 902.6, 903.6, 904.6, 905.6, 690.6 | |||
14 | Reinstall all detachable parts removed |
참조 문서
- ah0000n000501a 전기 용접 작업 시 차량 또는 부품 손상 방지 조치
- ah6000n000101a 차체 정비 관련 일반 지침
- ah6000n000501a 일반 용접 지침
- ah9100p000201m 에어백 유닛 또는 안전벨트 텐셔너 유닛이 장착된 차량에서의 정비 작업, 차체 작업, 용접 작업 실행에 관한 지침
- ar4230d8601b
- ar4230d8601c
- as0000z000701a 전기 용접 시 고전압으로 인한 사망 위험 인화성 물질이 있는 영역에서 실행하는 용접 작업에 의한 폭발 위험 용접 시 발생하는 불티 및 자외선으로 인한 상해 위험 용접 증기 흡입�
- as9100z000101d 에어백 유닛 혹은 안전벨트 텐셔너 유닛의 점검 작업 또는 정비 작업 중 상해 위험