Danger ! | Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury through burns to skin and eyes from battery acid or when handling damaged lead-acid batteries | No fires, sparks, open flames or smoking. Wear acid-resistant gloves, clothing and glasses. Only pour battery acid into suitable and appropriately marked containers. | |
| Notes on battery | ||
| Remove | ||
1 | Open maintenance flap | ||
2 | Disconnect ground line for on-board electrical system battery (G1) | ||
| Check | ||
3 | Visually inspect on-board electrical system battery (G1) for external leakage | ||
4 | Replace on-board electrical system battery (G1) | If the on-board electrical system battery is leaky (G1). | |
5 | Check on-board electrical system battery (G1) | ||
| 000 588 02 19 00 Battery tester | ||
Battery capacity 60 Ah | |||
6 | Reduce increased voltage after charging process | If the on-board electrical system battery (G1) is disconnected from the on-board electrical system and the message "Surface voltage detected" appears on the display of the battery tester/test equipment. | |
| 000 588 03 19 00 Load tester | ||
Check the on-board electrical system battery (G1) again after the increased voltage is reduced. | |||
7 | Charge on-board electrical system battery (G1) | With the test code "Charge and check" on the battery tester/test equipment. | |
Check the on-board electrical system battery (G1) again after charging. | |||
| Install | ||
8 | Connect ground line for on-board electrical system battery (G1) | ||
9 | Close maintenance flap |