W14.40-1472-08
1 | Holes | 4 | Screwdriver | 7 | Magnetic adapter | ||
2 | Fastening hook | 5 | Assembly aid | ||||
3 | Cover | 6 | AdBlue® tank |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | |||
| Remove | ||
1 | Unscrew cap (3) of the AdBlue® container (6). | ||
2 | Insert assembly aid (5) into the bores (1). | ||
| Assembly aid for removal/installation of magnetic adapter at AdBlue(R) tank filler neck | ||
3 | With two screwdrivers (4), press the fastening hooks (2) inward in the direction of the arrow and displace assembly aid (5) up to the end stop. | ||
4 | Pull out magnetic adapter (7). | ||
| Install | ||
5 | Press together the fastening hooks (2) by hand and insert assembly aid (5) up to end stop into the bores (1). | ||
| Assembly aid for removing/installing the magnet adapters on the filler neck of the AdBlue® container | ||
6 | Insert magnetic adapter (7) up to end stop into the filler neck of the AdBlue® container (6). | ||
7 | Hold magnetic adapter (7) and pull out assembly aid (5). | When pulling out the assembly aid (5), the fastening hooks (2) engage audibly. | |
8 | Screw on cap (3) of the AdBlue® container (6). |
참조 문서
- ah1440n000101a AdBlue 사용, 재료 특성 및 취급 관련 지침
- as1440z000101a AdBlue 라인과 이와 연결된 부품에서 작업 시 입을 수 있는 화상 위험 AdBlue 취급 시 피부와 안구의 상해 위험 AdBlue 음용으로 인한 중독 위험
- wf5850w144001a