G49.20-3214-08
1 | Metering device | 3 | Electrical connector | ||||
2 | Sealing ring | 4 | AdBlue® pressure sensor |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Note on calculation of tightening torque when using insertion or socket tools with various effective lengths | |||
Notes on use, material properties and handling of AdBlue® | |||
| Remove/install | ||
1 | Switch off ignition. | ||
2 | Disconnect electrical connector (3) from AdBlue® pressure sensor (4). | ||
3 | Remove AdBlue® pressure sensor (4). | AdBlue® SCR pressure sensor to metering device | |
4 | Install in the reverse order. |