ar4340d1700ad

Remove/install solenoids of Telma retarder

유형 ar · 주제 43.40 · 버전 0100 · 2006-07-26

적용 대상: MODEL 668, 670 with CODE (BR3) CC 80 retarder

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 2 섀시 › 43 브레이크-공압장치 및 보조브레이크 › 43.40 리타더 (전기식) — 시리즈 668 · 시리즈 670

EinPAS 21 브레이크/진공압 시스템/압축 공기 시스템 › 21.21 리타더 › 21.21.30 하우징/커버/샤프트/리타더 — 시리즈 668 · 시리즈 670

AR43.40-D-1700AD

Remove/install solenoids of Telma retarder

10.4.06

MODEL 668, 670 with CODE (BR3) CC 80 retarder

Remove/install solenoids of Telma retarder

D43.40-0012-09

Illustration shows bottom rear solenoid of circuit 4

5 Electrical connections

6 Insulating washer

7 Guard plate

1 Pole plate

2 Dowel pin

3 Corrugated washer

4 Solenoid

Remove/install

1

Check power consumption of retarder

The measured values must be within the tolerance.
If one of the measured values is outside the tolerance, the electrical connections (5) should be disconnected from the retarder solenoids (4) and each solenoid (5) must be measured separately.

AR43.40-D-1050-02AD

Current per circuit

*BE43.40-N-1003-01B

*WH58.30-Z-1001-09A

*WH58.30-Z-1016-09A

2

Expose electrical connections (5) of solenoid (4) to be removed

Installation: The electrical connections must be routed in such a way that they do not rub against other components.

3

Mark and disconnect electrical connections (5)

Installation: Only the crimp-type connectors intended for this purpose should be used.

Connection diagram for solenoids of Telma retarder

AH43.40-N-0001-01AD

4

Check solenoid (4) by measuring ohms

Only replace the solenoid (4) if the value is outside the tolerance.

Resistance of retarder solenoid

*BE43.40-N-1002-01B

*WH58.30-Z-1001-09A

5

Remove appropriate retarder rotor

AR43.40-D-1600AD

6

Remove pole plate (1) of appropriate solenoid (4)

Pay attention to dowel pin (2).

*BA43.40-N-1004-01B

7

Remove corrugated washer (3)

8

Remove solenoid (4) with insulating washer (6) and guard plate (7)

Pay attention to the installation position of the solenoid (4).

Installation: Make sure that the notch (arrow A) on the guard plate (7) is aligned with the connections (arrow B) of the solenoid (4). The connections (arrow B) of the solenoid (4) must not make contact with the stator.

9

Install in the reverse order

10

Check power consumption of retarder

AR43.40-D-1050-02AD

Current per circuit

*BE43.40-N-1003-01B

*WH58.30-Z-1001-09A

*WH58.30-Z-1016-09A

Test values for retarder (electric)

Number

Designation

Model
668, 670 with
code BR3

BE43.40-N-1002-01B

Resistance of retarder solenoid

at 20°C

Ω

1.19 (20%)

BE43.40-N-1003-01B

Current per circuit

at 24 V and 20 °C

A

20 (20%)

at 12 V and 20 °C

A

40 (20%)

Retarder

Number

Designation

Model
668, 670
with code BR3

BA43.40-N-1004-01B

Pole plate for solenoid to stator

M10

Nm

30

Commercially available tools

Number

Designation

WH58.30-Z-1001-09A

Multimeter

WH58.30-Z-1016-09A

Clamp-on probe

참조 문서