AR42.30-D-9865A | Remove/install pressure sensor at ABD hydraulic unit | 27.4.12 |
MODEL MODEL 901.6, 902.6, 903.6, 904.6 with CODE (GD5) Automated manual transmission 716.643
D42.30-1117-11
1 Pressure sensor connector
2 Pressure sensor
3 Hydraulic unit with control unit
| Remove, Install | ||
Danger! | Risk of poisoning caused by swallowing brake fluid. Risk of injury caused by brake fluid coming into contact with skin and eyes | Only pour brake fluid into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling brake fluid. | |
| Brake fluid notes | ||
| Notes on repairs to brake system | ||
| Important notes concerning repair work on the antilock brake system (ABS) | ||
1 | Unplug connector (1) | Press side tab of connector to disengage. Installation: Tab of connector must latch audibly into place. | |
2 | Remove pressure sensor (2) | Seal off connection at hydraulic unit to prevent any soiling. | |
| |||
Installation: Thread and sealing surface at pressure switch and hydraulic unit must not exhibit any signs of damage. Reworking is not permitted. If a part is damaged it must be replaced. | |||
3 | Bleed brake system, check for leaks and proper function | Start the engine to carry out function check. Warning lamps must go out. Press the brake pedal firmly several times. Warning lamps must not light up. | |
4 | Check fluid level in reservoir and correct if necessary | ||
| |||
5 | Connect STAR DIAGNOSIS, read and erase diagnostic trouble code memory | ||
6 | Print out protocol |