AR28.18-P-0001GR | Remove/install differential lock vacuum pump | 19.4.12 |
MODEL 463.222 /243 /244 /245 /246 /247 /248 /249 /250 /254 /270 /271 /303 /340 /341
MODEL 463.202 /236 /237 up to model year 2013
/model refinement package 2012
P28.18-2002-08
Shown on model 463.248
1 Vacuum hose
2 Electrical connector
M40 Remove differential lock vacuum pump
3 Nut
P28.18-2005-08
Shown on model 463.237
1 Vacuum hose
2 Electrical connector
M40 Remove differential lock vacuum pump
3 Nut
| Remove/install | ||
1 | Disconnect vacuum hoses (1) from differential lock vacuum pump (M40) | ||
2 | Remove right air intake pipe | Only on model 463.202/222/236/237 | |
3 | Disconnect electrical connector (2) | ||
4 | Unscrew nuts (3) | ||
5 | Remove differential lock vacuum pump (M40) | ||
6 | Install in the reverse order | ||
| Checking | ||
7 | Check overall operation of differential lock actuation |