AR27.19-D-4980A | Remove/install pilot bushing of electrohydraulic controller unit | 15.2.12 |
TRANSMISSION 722.681 in MODEL 902.6, 903.6, 904.6, 905.6
TRANSMISSION 722.681 in MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7
D27.19-1124-04
1 O-rings
2 Pilot bushing
3 Screw
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect battery ground line | Isolate ground lead to prevent accidental contact. | |
| Notes on battery | ||
2 | Detach electrical connector. | ||
3 | Unscrew bolt (3) and remove pilot bushing (2) | Catch oil running out. | |
4 | Install in the reverse order |
참조 문서
- ah5410p000101a 배터리 관련 지침
- ah5410p000101a
- ar2719d075001b
- as5410z000101a 단락 및 폭발성 기체 유출로 인한 화재/폭발 위험 배터리 전해액/증기, 단락 및 전기 아크에 노출 시 눈, 피부, 점막의 부식으로 인한 화상/상 해 위험 배터리 전해액을 삼키거나 피부