1 | Metering device |
2 | Injection line |
3 | Injection nozzle |
D14.40-0003-12
| Remove/install | ||
1 | Remove maintenance hood | ||
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
2 | Remove injection line (2) on metering line (1) and injection nozzle (3) | ||
Notes on use, material properties and handling of AdBlue® | |||
Seal bores with suitable stop plugs. | |||
Installation: Check injection line (2) and injection nozzle (3) for foreign objects and contamination; clean if necessary. | |||
Union nut, injection line to metering device | |||
Union nut, injection line to injection nozzle | |||
3 | Install in the reverse order |
참조 문서
- ah1440n000101a AdBlue 사용, 재료 특성 및 취급 관련 지침
- as1440z000101a AdBlue 라인과 이와 연결된 부품에서 작업 시 입을 수 있는 화상 위험 AdBlue 취급 시 피부와 안구의 상해 위험 AdBlue 음용으로 인한 중독 위험