W14.40-1519-09
1 | Metering unit | 3 | Strainer | 5 | Compressed air inlet | ||
2 | Compressed air piping | 4 | Screwdriver |
Remove/install | |||
1 | Open the engine access cover | ||
2 | Remove the compressed air piping (2) at the metering device (1) | Plug the hole with a suitable sealant. | |
Wait until the pressure is released before starting any work on the exhaust gases treatment system. | |||
Installation: Before mounting, inspect the compressed air tubing connection (2) for impurities, contaminants and damage. | |||
.Compressed air line hollow bolt on dosage unit | |||
3 | Remove the filter (3) using a screwdriver (4) | ||
Warning | Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running. | Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts. | |
4 | Install in reverse order. | ||
5 | Start the engine | ||
6 | Check the tightness of the dosing unit (1) with the engine running |
참조 문서
- as0000z000501a 엔진이 작동 중인 상태에서 급발진에 의한 사고 위험 시동 또는 구동 중인 엔진 근처에서 작업할 때 차량에 부딪히거나 열에 의한 상해 위험