W14.40-1184-08
1 | Metering unit | 3 | Electrical connector | ||||
2 | O-Ring | B128 | SCR compressed air pressure sensor |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | . | ||
| Remove/install | ||
Warning | Risk of injury caused by body parts being pinched or crushed as cab is tilted | Ensure that no one is within the tilting range of the cab as it is being tilted. Always tilt the cab all the way to the end position and secure with the safety strut. | |
1 | Turn off ignition | ||
2 | Tilt the cabin | ||
Topical note | Notes on tilting the cab | . | |
3 | Detach the electric connector (3) in the SCR compressed air pressure sensor (B128) | ||
4 | Remove the pressure sensor from the SCR compressed air (128) | AdBlue compressed air pressure sensor SCR on dosage unit | |
5 | Install on the reverse order |
참조 문서
- ah1440n000101a AdBlue 사용, 재료 특성 및 취급 관련 지침
- ah6080n000301a 캡 틸팅 관련 지침
- as1440z000101a AdBlue 라인과 이와 연결된 부품에서 작업 시 입을 수 있는 화상 위험 AdBlue 취급 시 피부와 안구의 상해 위험 AdBlue 음용으로 인한 중독 위험
- as6080z000101a 캡이 틸팅될 때 신체의 일부가 끼이거나 눌려서 발생하는 상해 위험