AR14.20-D-7666SF | Remove/install housing for exhaust gas recirculation valve | 24.10.06 |
ENGINE 642.992 in MODEL 906
D14.20-1115-08
1 Housing
2 Bolts
3 Bolts
Y27/11 Exhaust gas recirculation positioner
4 Bolts
5 Coolant hoses
6 Electrical connector
| Remove/install | ||
1 | Drain coolant | ||
2 | Remove fan shroud | ||
3 | Detach coolant hoses (5) at exhaust gas recirculation positioner (Y27/11)) | ||
4 | Remove bolts (2, 3, 4) | ||
5 | Remove housing (1) until the electrical connector (6) is reachable | ||
6 | Disconnect electrical connector (6) | ||
7 | Install in the reverse order | ||
| Check | ||
Danger! | Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns from working on the vehicle as it is being started or when the engine is running | Secure vehicle to prevent it from starting off by itself. | |
8 | Test run engine and check leaktightness in the area of housing (1) |