AR09.41-D-1311D | Remove/install charge air pipe | 15.2.12 |
ENGINE 904.904 in MODEL 670
ENGINES 904.908 /914 /923 /936 in MODELS 668, 670
D09.41-0003-06
1 Charge air pipe
2 Clip
3 Bolt
4 Bolt
5 Charge air hose (red)
6 Hose clamp
7 Sealing ring
| Remove/install | ||
1 | Switch off ignition | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
2 | Disconnect ground lead from battery | ||
| Notes on battery | All models | |
3 | Remove air intake hose | ||
4 | Detach hose clamp (6) on charge air hose (5) | Inspect condition of hose clamp (6), replace if necessary. | |
5 | Remove bolt (3) and clamp (2) on charge air pipe (1) | Inspect condition of clamp (2), replace if necessary. | |
6 | Remove bolt (4) and charge air pipe (1) from turbocharger | | |
Installation: Replace seal (7). | |||
7 | Pull charge air pipe (1) out of charge air hose (5) and remove upwards | ||
8 | Install in the reverse order |