AP09.10-T-0980-02A | Wash air cleaner element | ||
Danger! | Pay attention to instructions of manufacturer | Wear rubber gloves or protect hands with skin cream! |
On no account use soapy suds for washing the air cleaner element
1 After blowing out cleaner element soften for about 10 min. in a washing solution of about 40 °C.
2 Move cleaner element back and forward for about 5 minutes in the washing solution.
3 Rinse cleaner element in clean water until the water which flows off is clear.
4 Spin-dry cleaner element by hand and dry at a maximum drying temperature of
60 °C in a dust-free environment.
Only dry cleaner elements should be built-in.