Application of sealing product on the cylinder head front cover
After cleaning the sealing surfaces properly, apply a 1.5 0.5 mm thick strand of sealing product on the marked area (arrows)
Install the cylinder head front cover 10 minutes after applying the sealing product.
If the standby time is not respected, this may lead to leakage.
Do not lubricate the sealing product strand.
Use only the recommended sealing product.