ad8050d4000a

Anti-theft alarm system (ATA) diagnosis fault memory (fault code list)

유형 ad · 주제 80.50 · 버전 0102 · 2003-06-13

적용 대상: MODEL 901, 902, 903, 904 with CODE (J67) Anti-theft alarm system

“ko”(으)로는 제공되지 않아 영어(으)로 표시합니다.

위치

기능 그룹 3 구조 › 80 중앙잠금장치, 편의조작부, 운전자 인증시스템 › 80.50 침입-도난-경보장치 (EDW), 실내보호장치/견인방지장치 — 시리즈 901 · 시리즈 902 · 시리즈 903 · 시리즈 904

AD80.50-D-4000A

Anti-theft alarm system (ATA) diagnosis fault memory (fault code list)

23.7.97

MODEL 901, 902, 903, 904 with CODE (J67) Anti-theft alarm system

Anti-theft alarm system (ATA) diagnosis previous knowledge

AD80.50-D-2000A

Battery voltage 11-14 V

Complete ATA system (all connectors connected)

Central locking and remote radio control (FFB) in order

Turn signal system in order

The cables, connectors and plug-in connections are taken into consideration during testing using the HHT, and may need to be separately re-tested for breaks, good contact and correct connection as per the relevant circuit diagram a fault is indicated.

Connect Hand-held Tester (HHT)

AD00.00-D-2000-03A

Fault memory

Fault code

Fault text (HHT)

Note

Remedy

Door contact

Door contact switch

Cable –

Tailgate contact

Sliding door/tailgate switch

Cable –

Faulty control module

Try replacing the control module

No connection to central locking system

Cable –

Faulty connection to central locking system

Interference

Try replacing central locking system control module

Activate door lock switch

Door lock switch

Cable –

Deactivate door lock switch

Door lock switch

Cable –

참조 문서