AD80.35-D-6003-07A | DAS control lead, testing IMM electrical system |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Control cable PWM -//- | A13.2 12 |
| A53 5 | Ignition: OFF Sockets of WSP and PMS control units disconnected | <5 Ω | Cable |
1.1 | - |
|
| A53 5 | Ignition: OFF Sockets of WSP and PMS control units disconnected | >20 kΩ | Cable |
1.2 | + |
|
| A53 5 | Ignition: OFF Sockets of WSP and PMS control units disconnected Ignition: ON |
<1 V | Cable Further possibilities: PMS or WSP control unit (read PMS fault memory with HHT) |