AD80.35-D-6002-05A | RFL test of electrical system drive authorization system control line | M 111 |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Control line PWM -//- | A13.2 12 |
| A25.1 5 | Ignition: OFF Sockets of RFL and PEC control modules disconnected | <1 Ω | Cable |
1.1 | - |
|
| A25.1 5 | Ignition: OFF Sockets of RFL and PEC control modules disconnected | >20 kΩ | Cable |
1.2 | + |
|
| A25.1 5 | Ignition: OFF Sockets of RFL and PEC control modules disconnected Ignition: ON |
<1 V | Cable Further possibilities: PEC or RFL control module (read PEC fault memory with HHT) |