AD80.20-D-6001-56A | Control switch, passenger door, testing CL electrical system |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Operation of command switch Passenger door | 5 | | 10 | Connector unplugged from control module A8 Passenger door closed Unlock passenger door Lock passenger door measured at connector of control module |
5 Ω > 5 Ω | Wiring Command switch |
1.1 | Operation of command switch | 4 | | 10 | Unlock passenger door Lock passenger door measured at connector of control module | > 5 Ω 5 Ω | Wiring Command switch |