AD80.20-D-6001-54A | Rotary tumbler switch/actuator, passenger door, testing CL electrical system |
| Scope of test | Tester/test connection | Operation/ Requirement | Specified value | Possible cause/ Remedy | ||
1.0 | Operation of rotary tumbler switch Passenger door | 4 | | 10 | Connector unplugged from control module A8 Open passenger door Close passenger door measured at connector of control module |
5 Ω > 5 Ω | Wiring Rotary tumbler switch |
1.1 | Operation of rotary tumbler switch and actuator motor | 11 | | 10 | Open all other doors Open passenger door measured at connector of control module | 10 Ω > 10 Ω | Wiring Rotary tumbler switch |