AD07.13-D-6000-17A | Preglow indicator lamp relay test of electrical system diesel injection system (EDC) |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Preglow indicator lamp relay (K45) Preglow indicator lamp relay |
85 | K45 |
86 | Ignition: OFF Preglow indicator lamp relay disconnected | approx. 90 Ω | Preglow indicator lamp relay (K45) |
1.1 | Cable |
53 | |
55 | Ignition: OFF Coupling on control unit disconnected Preglow indicator lamp relay connected | approx. 90 Ω | Cable Specified value in order: MSA control unit (A20) |