AR83.30-L-5300A | Remove/install A/C compressor | 12.7.10 |
MODEL 667, 668, 670 with CODE (H03) Air conditioning in front section
L83.30-0005-12
Shown on refrigerant compressor of 904 engine
1 Bolt
2 Manifold
3 Seals
4 AC compressor
5 Combination bracket
6 11/16" screw-in pipe connection
7 7/8" screw-in pipe connection
8 Refrigerant line, low pressure
9 Refrigerant line, high pressure
10 Screw
11 Washer
L83.30-0006-01
12 Connector
| Remove/Install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning. Inhaling overheated refrigerant vapors may be toxic. Risk of injury. Contact with liquid refrigerant may result in injury to the skin and eyes. | Do not carry out any welding work on the closed air conditioning system or in the surrounding area. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
Danger! | Risk of accident from vehicle starting off by itself when engine running. Risk of injury from bruises and burns if you place your hand into the engine when it is started or when it is running. | Secure vehicle to prevent it from moving off by itself. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
| Notes on handling refrigerant R134a | All models with R134a refrigerant | |
1 | Discharge air conditioning system | ||
2 | Remove poly V-belt | Engine 602.984/985 | |
Engines 904.904/908/923 | |||
3 | Remove connector (12) | Mark connector (12). | |
4 | Disconnect refrigerant lines (8, 9) from screw-in pipe connections (6, 7) | 7/8" screw-in pipe connection, refrigerant compressor to refrigerant line | |
11/16" screw-in pipe connection, refrigerant compressor to refrigerant line | |||
5 | Unscrew bolts (10). | Bolt, refrigerant compressor to combination holder | |
6 | Remove refrigerant compressor (4) | Together with manifolds (2) and refrigerant lines (8, 9). | |
7 | Unscrew screws (1) | Bolt, manifold to connecting piece | |
8 | Remove manifold (2) | Installation: Install new sealing rings (3). | |
9 | Remove refrigerant compressor connecting piece (4) | ||
10.1 | Replace refrigerant compressor (4) | Follow-up work: | |
Remove expansion valves | |||
Total capacity | |||
10.2 | Reconditioning refrigerant compressor (4) | Follow-up work: | |
Remove refrigerant compressor cylinder roller bearing (4) | |||
Remove electromagnetic clutch | |||
Remove refrigerant compressor shaft seal (4) | |||
Total capacity | |||
11 | Replace receiver/drier | The fluid reservoir must be replaced whenever work is carried out in the air conditioning system. | |
12 | Install in the reverse order | ||
| Inspecting | ||
13 | Evacuate air conditioning system and check for leaks | ||
14.1 | Fill and top up air conditioning system (gaseous) | ||
14.2 | Fill air conditioning system (liquid) | ||
15 | Check function of air conditioning | Run engine at idling speed for about 5 minutes and check all the component functions which are of relevance for proper operation of the air conditioning system. | |
16 | Perform quick test on air conditioning system |
Air conditioning
Number | Designation | Models 667, | |
BA83.40-N-1002-01B | Bolt, manifold to connector | Nm | 23 |
BA83.40-N-1003-01B | Bolt, A/C compressor to combination bracket | Nm | 23 |
BA83.40-N-1004-01B | Pipe union 7/8", A/C compressor to refrigerant line | Nm | 33 (4) |
BA83.40-N-1005-01B | 11/16" screw-in pipe connection, refrigerant compressor to refrigerant line | Nm | 44 (4) |
Air conditioning system
参照文書
- ah8330n000301a 冷媒 (R134a) の取扱いについての注意事項
- ah8330n000501a リペア作業時のエアコンの冷媒回路および構成部品の水分付着からの保護
- ar1322d1202b V ベルトの脱着
- ar1322d1202d
- ar8330l1209a
- ar8330l1762a
- ar8330l1767a
- ar8330l1777a
- ar8330l1780a
- ar8330l5530a
- ar8330l6520a
- ar8330l7682a
- ar8330l7686a
- ar8355l1100a
- ar8355l5350a
- as0000z000501a エンジン作動中に車両がひとりでに動き出す危険があります。 スタート時または作動中のエンジンに接触すると、巻き込まれて負傷をする、または火傷をする危険があります。
- as8300z000101a 密閉したエアコンに対して溶接作業またはハンダ付け作業を行うことによる爆発の危険。加熱した冷媒のガスを吸い込むことによる中毒の危険。肌や眼に液状の冷媒が触れるこ�