ar0716g1007h

Fill fuel low-pressure circuit on engine

種別 ar · トピック 07.16 · バージョン 0105 · 2018-08-09

適用: Engine 470.9, 471.9, 473.9 in model 800.310/320

「ja」では利用できません。英語で表示しています。

位置付け

機能グループ 1 エンジン › 07 混合気生成 › 07.16 コモン・レール・ディーゼル・インジェクション・システム — シリーズ 470(モデル 9**) · シリーズ 471(モデル 9**) · シリーズ 800(モデル 310, 320)

EinPAS 16 エンジン燃料/パワーサプライ › 16.10 燃料供給システム › 16.10.1 基本情報 — シリーズ 470(モデル 9**) · シリーズ 471(モデル 9**) · シリーズ 800(モデル 310, 320)

エンジン/トランスミッションにも適用: 473 9**

AR07.16-G-1007H

Fill fuel low-pressure circuit on engine

08.08.2018

Engine

470.9, 471.9, 473.9 in model 800.310/320

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Danger

Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel.

No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only.
Wear protective clothing when handling fuel.

AS47.00-Z-0001-01A

Filling

1.1

Fill fuel low-pressure circuit on engine with hand pump

If no repair work was performed on the fuel system high pressure pump and if the fuel low-pressure circuit should not be filled with the filling unit.

Engine 470.9, engine 471.9 as of engine end number 032691, engine 473.9

AR07.16-W-1007-01HA

Engine 471.9 up the engine end number 032690

AR07.16-W-1007-01H


The fuel low-pressure circuit must be filled using the filling unit after repairs on the fuel system high pressure pump.
The fuel system high pressure pump will be damaged during starting otherwise.

1.2

Fill fuel low-pressure circuit on engine with filling unit

If no repair work was performed on the fuel system high pressure pump and if the fuel low-pressure circuit should not be filled with the hand pump.

AR07.16-W-1007-02H

000 588 00 71 00 Pump

WS47.00-N-0018B

参照文書