gf4920g3025a

AdBlue(R) heating coolant solenoid valve, component description

Tipo gf · tema 49.20 · versione 0100 · 2019-12-16

Valido per: Engine 900.91/92 in model 000.001 with BlueTec Engine 902.91/93 in model 000.001 with BlueTec Engine 904.94/95/96/97 in model 000.001 with BlueTec Engine 906.93/94/95/96/98/99 in model 000.001 with BlueTec Engine 924.91/93/94 in model 000.001 with BlueTec Engine 925.9 in model 000.001 with BlueTec Engine 926.91/92/93/95/97/98 in model 000.001 with BlueTec

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 1 Motore › 49 Impianto di scarico, depurazione dei gas di scarico › 49.20 Post-trattamento dei gas di scarico — Serie 000 (modelli 001) · Serie 900 (modelli 91*, 92*) · Serie 902 (modelli 91*, 93*) · Serie 904 (modelli 94*, 95*, 96*, 97*) · Serie 906 (modelli 93*, 94*, 95*, 96*, 98*, 99*)

Valido anche per motori/cambi: 924 91*, 924 93*, 924 94*, 925 9**, 926 91*, 926 92*, 926 93*, 926 95*, 926 97*, 926 98*

GF49.20-G-3025A

AdBlue(R) heating coolant solenoid valve, component description

27.11.2019

Engine

900.91/92 in model 000.001

with BlueTec

Engine

902.91/93 in model 000.001

with BlueTec

Engine

904.94/95/96/97 in model 000.001

with BlueTec

Engine

906.93/94/95/96/98/99 in model 000.001

with BlueTec

Engine

924.91/93/94 in model 000.001

with BlueTec

Engine

925.9 in model 000.001

with BlueTec

Engine

926.91/92/93/95/97/98 in model 000.001

with BlueTec

AdBlue(R) heating coolant solenoid valve, component description

Location
The AdBlue® heater coolant solenoid valve is located at the rear on the engine at the height of the cylinder head.

Y107

AdBlue® heater coolant solenoid valve

W14.40-1267-06

Task

Via the AdBlue® heater coolant solenoid valve, coolant is diverted off from the engine coolant circuit to heat the AdBlue® line circuit, AdBlue® tank and AdBlue® pump module.

AdBlue(R) heating coolant solenoid valve, component description

Structure

1

Electrical connector

2

Coolant inlet

3

Coolant outlet

Y107

AdBlue® heater coolant solenoid valve

G49.20-A054-02

The AdBlue® heater coolant solenoid valve (Y107) is a 2/2-way valve with two line fittings for coolant lines. Inside the valve, the valve body is designed as a solenoid armature.

Function

The AdBlue® heater coolant solenoid valve is actuated by the motor control module (MR) (A6). Via the AdBlue® fill level sensor/temperature sensor (B117), the motor control module (MR) detects whether the temperature of the AdBlue® is approaching the limit value of 8 °C.

If the coolant reaches a temperature above 65 °C and the AdBlue® temperature reaches the limit value, the AdBlue® heater coolant solenoid valve is actuated by the motor control module (MR). The valve then opens and coolant is branched off from the engine's coolant circuit.

In the case of a non-opened AdBlue® heater coolant solenoid valve, the coolant is present at the closed valve body inside the component. This valve body keeps the passage between the coolant supply line and the coolant working line closed by the force of a compression spring.

When current is applied, the valve body moves and the opening is opened so that coolant can flow through. Once the current supply to the AdBlue® heater coolant solenoid valve is interrupted, the spring presses the valve body back into its starting position. This means that the passage is blocked off again.