gf4260b3110b

Four-circuit safety valve, location/task/design/function

Tipo gf · tema 42.60 · versione 0100 · 2016-02-12

Valido per: Vehicles 693; 694 and 695 682 and 384.067/.070/.071/.073/.074/.081/.083/.084/.085 693.154/.196/.367; 695.034/.051 and 696.080/.090/.365/.369

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 2 Telaio › 42 Freni impianto idraulico e meccanico › 42.60 Complesso pneumatico — Serie 693 · Serie 904 (modelli 925)

EinPAS 21 Freni/impianto di depressione/impianto pneumatico › 21.35 Impianto pneumatico › 21.35.13 Tubazione/flessibile/valvola — Serie 693 · Serie 904 (modelli 925)

GF42.60-B-3110B

Four-circuit safety valve, location/task/design/function

12.02.16

Vehicles 693; 694 and 695

682 and 384.067/.070/.071/.073/.074/.081/.083/.084/.085

693.154/.196/.367; 695.034/.051 and 696.080/.090/.365/.369

Four-circuit safety valve, location/task/design/function

B42.60-0326-01

Provision

1 4-circuit protecting valve (APU) (4.03)

Purpose

Ensure pre-established safety pressure for the brake system in case of a circuit fault. Pressurization to 21 and 22 service brake circuits takes priority.

4-circuit protecting valve - operation

Knorr Valve

GF42.60-B-3110-03C