gf4260b310001a

Single-chamber air drier with pressure regulator function

Tipo gf · tema 42.60 · versione 0100 · 2016-02-12

Valido per:

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 2 Telaio › 42 Freni impianto idraulico e meccanico › 42.60 Complesso pneumatico — Serie 368 · Serie 384

EinPAS 21 Freni/impianto di depressione/impianto pneumatico › 21.35 Impianto pneumatico › 21.35.30 Deumidificazione/regolazione/pulizia — Serie 368 · Serie 384

GF42.60-B-3100-01A

Single-chamber air drier with pressure regulator function

Single-chamber air drier with pressure regulator function

B42.60-0052-06

Structure

a Air dryer element

b Check valve

c Connection hole

d Valve

e Pre-filter

f Camera

g Diaphragm

1.01 Air compressor

4.03 Four circuit protective valve

5.01 Regeneration tank

A Supply pressure

Operation

In the pneumatic supply system phase, air from the compressor flows into the inlet chamber through the connection (1). Some preliminary condensation of water that may occur in this phase is collected and sent to the valve (d) through the connection hole (c).

Air entering connection 1 through the pre-filter (e) located within the air dryer housing, passes through the camera (f) and infiltrates the dryer element (a). Humidity contained in the compressed air is extracted when the air infiltrates the dryer element and the dry air passes through the check valve (B) and flows through the outlet connection (21).

The compressed air also flows through the connection hole (c) of connection (21) to connection (22) which is connected to the regeneration tank.

When the pressure of the pneumatic system reaches the maximum level, the air pressure in chamber (D) overcomes the force of the spring acting on diaphragm (d) and allows the air flow to the atmosphere through the outlet (3). At this stage, the air in the regeneration tank returns through connection (22) by removing the humidity from the dryer element (a) because the pressure acting on chamber (f) and ducts (A) and (C) is lower than the pressure contained in the regeneration tank.