ar4920g0014ch

Flush metering device of exhaust gas aftertreatment system

Tipo ar · tema 49.20 · versione 0100 · 2018-12-10

Valido per: Engine 457.9, 458.9 in model 000.001 with BlueTec

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 1 Motore › 49 Impianto di scarico, depurazione dei gas di scarico › 49.20 Post-trattamento dei gas di scarico — Serie 000 (modelli 001)

EinPAS 15 Motore › 15.40 Impianto di scarico/post-trattamento dei gas di scarico › 15.40.51 Pompa/dosatore/ugello — Serie 000 (modelli 001)

Valido anche per motori/cambi: 457 9**, 458 9**

AR49.20-G-0014CH

Flush metering device of exhaust gas aftertreatment system

05.06.2018

Engine

457.9, 458.9 in model 000.001

with BlueTec

Flush metering device of exhaust gas aftertreatment system

1

Metering device

2

Compressed air gun

3

Flushing hose

4

Test connection

A

Water column (4 cm)

W14.40-1382-06

Flush metering device of exhaust gas aftertreatment system

1

Metering device

5

Syringe

6

Hole

7

SCR compressed-air pressure sensor

G49.20-3223-12

Warning

Risk of accident from vehicle starting off by itself when engine running. Risk of injury (bruises and burns) resulting from working on the engine while it is being started or when it is running.

Secure vehicle to prevent it from starting off by itself. Wear closed and snug-fitting work clothes. Do not touch hot or rotating parts.

AS00.00-Z-0005-01A

Warning

Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue

Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system.

AS14.40-Z-0001-01A

Notes on use, material properties and handling of AdBlue®

AH14.40-N-0001-01A

Flushing

1

Switch off ignition.

2

Connect diagnostic system.

See information from body manufacturer.

3

Retrofit test connection (4) on compressed air inlet of the metering device (1).

Only if no test connection (4) is installed.

AR49.20-G-2042CH

The test connection (4) can remain installed.

4

Remove SCR compressed-air pressure sensor (7).

AR49.20-G-1080CH

5

Pour water into the bore (6).

Pour in water until it overflows from the bore (6).

6

Install SCR compressed-air pressure sensor (7).

AR49.20-G-1080CH

7

Connect flushing hose (3) to the test connection (4).

Use the measuring hose as a flushing hose (3).

Measuring hose

*360589002103

8

Remove valve from the flushing hose (3).

9

Pour water into the flushing hose (3) until a water column (A) of 4 cm is achieved.

During this process, hold the flushing hose (3) at a height so that the water flows in the direction of the test connection (4).

10

Screw valve into the flushing hose (3).

11

Connect compressed-air gun (2) to the flushing hose (3).

12

Flush metering device (1).


Set pressure reducing valve to a maximum of 5.5 bar.
Otherwise, the metering device (1) may be damaged.

Pressurize the flushing hose (3) with compressed air until the water is completely removed.

13

Start engine.

See information from body manufacturer.

14

Check compressed air pressure on the metering device (1) using the vehicle diagnosis system and switch off engine.

Inquiry of "actual value 69".

If the value still lies outside the specified tolerance range in the vehicle diagnosis system after repeating,

replace diffuser and sieve on the compressed air inlet of the metering device (1).


AR49.20-G-2043CH


AR49.20-G-2050CH

15

Remove flushing hose (3).

The test connection (4) can remain installed.

16

Remove vehicle diagnosis system.

Flush metering device of exhaust gas aftertreatment system

360 589 00 21 03

Measuring hose