ar4260b0115a

Check single-chamber air drier with integral pressure regulator for function

Tipo ar · tema 42.60 · versione 0101 · 2020-03-26

Valido per: Model 368, 382, 384, 634, 688, 979 Model 384, 386, 693, 694, 695 Model 384, 386, 693, 695, 696 Model 688, 979

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 2 Telaio › 42 Freni impianto idraulico e meccanico › 42.60 Complesso pneumatico — Serie 368 · Serie 382 · Serie 384 · Serie 386 · Serie 634 · Serie 688 · Serie 693 · Serie 694 · Serie 695 · Serie 696 · Serie 979

EinPAS 21 Freni/impianto di depressione/impianto pneumatico › 21.35 Impianto pneumatico › 21.35.30 Deumidificazione/regolazione/pulizia — Serie 368 · Serie 382 · Serie 384 · Serie 386 · Serie 634 · Serie 688 · Serie 693 · Serie 694 · Serie 695 · Serie 696 · Serie 979

AR42.60-B-0115A

Check single-chamber air drier with integral pressure regulator for function

09.03.2020

Model

368, 382, 384, 634, 688, 979

Model

384, 386, 693, 694, 695

Model

384, 386, 693, 695, 696

Model

688, 979

Check single-chamber air drier with integral pressure regulator for function

1

Manometer

2

Regenerative reservoir

3

Connection

B42.10-0428-01

Check

1

Remove the piping from the compressed air regenerative reservoir (2) and place the connection (3) to allow installation of the manometer (1)

2

Connect the manometer (1) to the regenerative tank (2)

Test kit

*360589002100

3

Pressurize the compressed-air system until the pressure regulator's discharge occur

After discharge through the pressure regulator, observe the manometer (1) and check whether the regenerative reservoir has completely emptied.

If the regenerative reservoir (2) does not completely empty, causing air pressure inside, check for damage to the piping between the regenerative reservoir and the air drier.

.Pressure regulator

*BE42.60-B-1001-01A

4

Repeat the operation check

If pressure remains in the regenerative reservoir, replace the air dryer filter.

5

Remove the manometer (1) and the connection

6

Install the pressure regulator piping to the regenerative reservoir (2)

Pneumatic brake system

Number

Designation

Chassis 368.00/05/10/11/15; 382.07/08/11/12/15/17/18; 384.06/07/11/14/20/22/31/33; 634.001/011/012/014/061/071/081; 693.02/10/12/14/15/17/18/19/34/38; 694.00/02/04; 695.01/02/03/04/05; 695.30; 696.08/09; 696.36

Chassis 364, 384.08/09, 386, 388, 397, 660, 664, 682, 688

BE42.60-B-1001-01A

Pressure regulator

Opening pressure - Wabco/Knorr

bar

9,8 ... 10,2

7,9 ... 8,3

Closing pressure - Wabco/Knorr

bar

8,7 ... 9,3

6,9 ... 7,7

Service pressure - Wabco/Knorr

bar

13

12

Opening pressure of safety valve - Wabco/Knorr

bar

14,5 ... 17,0

12,0 ... 15,0

Tires filling safety valve opening pressure - Wabco

bar

-

9,0 ... 13,0

Admissible leakage - Wabco/Knorr

bar (menor ou igual cm3)

10

10

Pressure on the test stand feeding circuit - Wabco/Knorr

bar

15

10

Pressure applied to the port 1 for leak test - Wabco/Knorr

bar

10

7

Pressure applied on the port 21 for leak test - Wabco/Knorr

bar

10

7

Pneumatic brake system

Number

Designation

Chassis 979.046

BE42.60-B-1001-01A

Pressure regulator

Opening pressure - Wabco/Knorr

bar

7,9 ... 8,3

Closing pressure - Wabco/Knorr

bar

6,9 ... 7,8

Service pressure - Wabco/Knorr

bar

13

Opening pressure of safety valve - Wabco/Knorr

bar

14,5 ... 17

Tires filling safety valve opening pressure - Wabco

bar

-

Admissible leakage - Wabco/Knorr

bar (menor ou igual cm3)

10

Pressure on the test stand feeding circuit - Wabco/Knorr

bar

15

Pressure applied to the port 1 for leak test - Wabco/Knorr

bar

10

Pressure applied on the port 21 for leak test - Wabco/Knorr

bar

10

Check single-chamber air drier with integral pressure regulator for function

360 589 00 21 00

Test kit