ar4260b004002a

Check working pressure, auxiliary consumer circuits 3 and 4

Tipo ar · tema 42.60 · versione 0100 · 2016-02-12

Valido per:

Non disponibile in “it”; mostrato in Inglese.

Collocazione

Gruppo funzionale 2 Telaio › 42 Freni impianto idraulico e meccanico › 42.60 Complesso pneumatico — Serie 382 (modelli 070, 073, 074, 083, 084, 085, 087) · Serie 693 · Serie 694 · Serie 695 · Serie 696 (modelli 080, 090, 365, 367, 369)

EinPAS 21 Freni/impianto di depressione/impianto pneumatico › 21.35 Impianto pneumatico › 21.35.1 Informazione basilare — Serie 382 (modelli 070, 073, 074, 083, 084, 085, 087) · Serie 693 · Serie 694 · Serie 695 · Serie 696 (modelli 080, 090, 365, 367, 369)

AR42.60-B-0040-02A

Check working pressure, auxiliary consumer circuits 3 and 4

Compressed air brake system

Número

Denominação

chassis 368.00/05/10/11/15; 382.07/08/12/15/17/18; 384.06/07/11/14/20/22/31/33; 634.001/011/061; 693.02/10/12/14/15/17/18/19/34/38; 694.00/02/04; 695.01/02/03/04/05; 695.30; 696.08/09; 696.36

BE42.60-B-1002-01A

Protective valve

Opening pressure - Wabco/Knorr - circuits 21 and 22

bar

8,7 ... 9,0

Opening pressure - Wabco/Knorr - circuits 23, 24, 25 and 26

bar

7,2 ... 7,5

Limiting valve opening pressure - Wabco - circuits 23, 24, 25 and 26

bar

8,1 ... 8,5

Closing pressure - Knorr - Circuits 21 and 22

bar

6,3

Closing pressure - Knorr - Circuits 23, 24, 25 and 26

bar

4,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco/Knorr - Circuits 21 and 22

bar

7,0

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Wabco - Circuits 23, 24, 25 and 26)

bar

4,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23, 24, 25 and 26

bar

5,5

Static closing pressure (without losses compensation and "0" bar in the defective circuit) - Knorr - Circuits 23 and 24

bar (bigger or equal)

-

Pressure limit - Wabco/Knorr - Circuits 23, 24, 25 and 26

bar

8,1 ... 8,5

Safety valve opening pressure - Knorr - Circuits 23, 24, 25 and 26

bar (bigger than)

8,2

Safety valve opening pressure - Knorr - Circuits 23, 24

bar (bigger or equal)

-

Pressure reduction (shifting pressure) - Knorr - Circuits 21 and 22

bar

10,4 ... 10,6

Pressure reduction (shifting pressure) - Knorr - Circuits 23 and 24

bar

8,4 ... 8,6

Pressure reduction (shifting range) - Knorr - Circuits 21, 22, 23 and 24

bar (bigger or equal)

0,5

Admissible leakage - Wabco

bar (smaller or equal to cm3/min)

10,0

Admissible leakage - Knorr

bar

8,0

Bench feeding circuit pressure - Wabco

bar

15,0

Bench feeding circuit pressure - Knorr

bar

11,8 ... 12,2

Pressure during the tightness test - Wabco

bar

10,0

Dynamic safety pressure - Knorr - Circuits 21, 22, 23 and 24

bar (bigger or equal)

-

Check working pressure, auxiliary consumer circuits 3 and 4

B42.60-0015-01

1 Install pressure gauges of the test box in circuits 23 and 24 and test socket (3).

2 Depressurize the pneumatic system below the opening pressure of the circuits 23 and 24 and turn on the engine.

3 Before taking place a discharge (exhaustion) in pressure regulator, adjust the opening pressure of circuits 23 and 24 (4) in four-circuit protection valve (4.03).
It is possible to increase the pressure when tightening adjusting screws. It is possible to drop the pressure when releasing adjusting screws.

4 Repeat the check.