001 589 53 21 00
Dial gage
055 589 03 21 00
Adjusting device
055 589 04 21 00
Template
B35.41-0009-01
1 | Install the master ring (3) on the check device (2) |
Observe the correct seating of the tabs (5) on the supporting pads (4) of the checking device (2). |
2 | Install the gauge (1) in the check device (2) and have its measuring tip touching the tray type slider of the device and this latter one touching the master ring edge (3) |
Apply a 2 mm pre-load on the gauge (1) |
3 | Fasten the gauge (1) and set the larger hand to zero |
4 | Remove the master ring (3) |
In this stage the check device will be ready to carry out the measurement in the housing of the tapered group. Note that the "zero" point of the gauge was obtained with a 2 mm pre-load. |
B35.41-0008-01