The image shows the 715.050 gearbox |
1 | Cover |
2 | Oil reservoir's upper side (maximum level of the liquid) |
3 | Oil reservoir's bottom side (minimum level of the liquid) |
W26.60-1142-05
Inspect | |||
Warning | Risk of injury to hands or eyes when working on hydraulic pressure reservoir systems caused by hydraulic fluid to specification 345.0 spraying out under pressure | Depressurize hydraulic pressure reservoir system before commencing work on system. Wear protective gloves and safety glasses. | |
1 | De-pressurize the automatic gear shift control pressure accumulator (AGS) |
| |
Depressurization is to be carried out preferably with Star Diagnosis, because the system may have up to 90 bar of pressure and the mechanic depressurization is an additional source of danger. | |||
.Pressure relief valve fastening | |||
2 | Inspect and correct the hydraulic oil level, if necessary | Before checking the hydraulic oil level at the reservoir, wait for approximately 5 min, as when the hydraulic oil pressure is removed, it foams as established in page 345.0. | |
The hydraulic oil level, when not under pressure, must always stay between the upper part of the oil reservoir's seam (2) and the bottom side of the oil reservoir seam (3). |
Documenti citati
- ar2610b002006ba
- as0000z002801a Pericolo di lesioni alla pelle o agli occhi durante i lavori su impianti idraulici di accumulo di pressione, dovute allo spruzzo di olio idraulico sotto pressione, secondo la specifica 345.0