Fan with electromagnetic coupling system - Linnig |
1 | Actuation connector |
2 | Fan |
3 | Nut |
4 | Electromagnetic clutch |
5 | Holder |
6 | Bolt |
7 | Fan pulley |
B20.40-0015-06
| Remove/install | ||
1 | Open the access cover to the engine compartment | Accumulation of dirt, chiefly on the coupling front face where the bimetallic blade is located, may cause inadequate fan operation. If necessary, clean with water, paying attention not to damage the two metal blade. | |
The access for carrying out the works and repairs vary according to the body type/manufacturer. | |||
Refer to the body makers instructions. | |||
2 | Remove the radiators | ||
3 | Unplug the drive connector (1) | ||
4 | Unscrew the bolts (6) and remove the drive pulley (7) | Check the drive belt for condition. Replace if necessary. | |
5 | Remove the nuts (3) from the electromagnetic clutch (4) to the bracket (5) | ||
6 | Remove the fan (2) from the electromagnetic clutch (4) | In the case of electromagnetic coupling failure, fasten the two bolts for the lock-up. After the maintenance, remove them. | |
At removal of the electromagnetic coupling, mark the corresponding bolt fitting holes for the repositioning. | |||
7 | Installation in reverse order |