W14.40-1505-08
1 | Metering unit | 3 | Electrical connector | ||||
2 | Sealing ring | B129 | AdBlue pressure sensor |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | . | ||
Remove/install | |||
Warning | Risk of injury caused by body parts being pinched or crushed as cab is tilted | Ensure that no one is within the tilting range of the cab as it is being tilted. Always tilt the cab all the way to the end position and secure with the safety strut. | |
1 | Turn off ignition | ||
2 | Tilt the cabin | ||
Topical note | Notes on tilting the cab | . | |
3 | Loose the electrical connector (3) from the AdBlue pressure sensor (B129) | ||
4 | Remove the AdBlue pressure sensor (B129) | AdBlue pressure sensor SCR on dosage unit | |
5 | Install on the reverse order |
Documenti citati
- ah1440n000101a Avvertenze sull'impiego, sulle caratteristiche e sulla manipolazione dell'AdBlue
- ah6080n000301a Avvertenze sul ribaltamento della cabina di guida
- as1440z000101a Pericolo di ustioni e scottature dovute a liquido bollente durante i lavori sulle tubazioni AdBlue e sui componenti ad esse collegati. Pericolo di lesioni alla pelle e agli occhi durante la manipolazione di AdBlue. Pericolo di
- as6080z000101a Pericolo di lesioni da incastro e schiacciamento durante il ribaltamento della cabina di guida