GF82.60-P-5000FL | Media interface control unit, component description | 13.3.12 |
MODEL 212
with CODE (518) Media Interface
up to model year 2013
/AEJ 12
P82.60-6557-06
Shown on model 212.0
N125/1 Media interface control unit
Location
The Media Interface control unit is located behind the glove compartment.
Task
Receive signals
Transmit signals
Receive signals
Direct lines
Media Oriented System Transport (MOST)
Direct lines
- Power supply via circuit 31 and circuit 30g
- Audio signals and data via the Media Interface electrical connector (X18/70) and "Mitsumi CAM62" connector
- Electronic wake-up for MOST
Media Oriented System Transport (MOST)
- Control and operating signals from the audio equipment
Transmit signals
Direct lines
MOST
Direct lines
- Power supply to Media Interface connector in general and for USB over "Mitsumi CAM62" connector
- Control signals to Media Interface connector over "Mitsumi CAM62" connector
MOST
- Audio signals and data to the audio unit
Technical data Designation |
Unit |
Values |
Tolerance range |
Remarks |
Media interface control unit | ||||
Power supply | V | 12 | Operating voltage (UB) | |
Voltage limits | V | >9 | Minimum (UBmin) | |
V | < 16 | Maximum (UBmax) | ||
Power consumption | mA | 300 | Ready (IB) | |
mA | 300 | Action, typical (IAction) | ||
A | 1.5 | Maximum (IAction) | ||
mA | 0.1 | Quiescent current | ||
Reverse polarity protection | Yes, in range -9 V to -16 V | |||
Flash capability/coding capability | No/DC-compatible |