If reinforcements or sheet metal panels are replaced below the A-pillar outer section, do not drill holes in connection surfaces accessible from both sides.
The holes required are installed later when fitting and installing
P63.20-6179-05
1 Scribe cuts on A-pillar outer section (1) according to old part removed along broken lines in areas A and B
2 Cut on A-pillar outer section (1) in areas A and B on side wall paneling (2)
P63.20-6180-12
3 Grind joints and connection surfaces down to bare metal in areas C and D on A-pillar outer section (1).
P63.20-6181-06
4 Drill holes for plug welding in illustrated areas on A-pillar outer section (1) and grind connection surfaces down to bare metal, on both sides.
P63.20-6182-11
5 Drill holes for plug welding in illustrated areas on A-pillar outer section (1) and grind connection surfaces down to bare metal, on both sides.