ar6110d572001b
Separate front floor in cab up to firewall
Tyyppi ar · aihe 61.10 · versio 0106 · 2006-07-25
Koskee: MODEL 901.31 /32 /42 /61 /62, 902.31 /32 /41 /42 /61 /62, 903.01 /02 /31 /32 /41 /42 /61 /62, 904.01 /31 /32 /41 /42 /61 /62, 905.61 /62 MODEL 690.61 MODEL XD2, XD3, XD4, XD5, XD6, XD7 MODEL 903.62, 904.62 with CODE (ZU9) National version for Mexico
Ei saatavilla kielellä ”fi”; näytetään kielellä Englanti.
Sijainti
Toimintoryhmä 3 Kori, päällysrakenne › 61 Korin (päällysrakenteen) alaosa › 61.10 Pohjalevy — Mallisarja 690 (mallit 61*) · Mallisarja 901 (mallit 31*, 32*, 42*, 61*, 62*) · Mallisarja 902 (mallit 31*, 32*, 41*, 42*, 61*, 62*) · Mallisarja 903 (mallit 01*, 02*, 31*, 32*, 41*, 42*, 61*, 62*) · Mallisarja 904 (mallit 01*, 31*, 32*, 41*, 42*, 61*, 62*) · Mallisarja 905 (mallit 61*, 62*)
EinPAS 35 Kori/runko/liittyvät osat › 35.32 Alapohja › 35.32.35 Pohjarakenne/alustakehikko — Mallisarja 690 (mallit 61*) · Mallisarja 901 (mallit 31*, 32*, 42*, 61*, 62*) · Mallisarja 902 (mallit 31*, 32*, 41*, 42*, 61*, 62*) · Mallisarja 903 (mallit 01*, 02*, 31*, 32*, 41*, 42*, 61*, 62*) · Mallisarja 904 (mallit 01*, 31*, 32*, 41*, 42*, 61*, 62*) · Mallisarja 905 (mallit 61*, 62*)
AR61.10-D-5720-01B
| Separate front floor in cab up to firewall
|
|
|
WE58.40-Z-1001-03A
| Drill (electric/pneumatic)
|
WE58.40-Z-1003-03A
| Angle grinder (electric/pneumatic)
|
WE58.40-Z-1004-03A
| Body saw (electric/pneumatic)
|
WE58.40-Z-1005-03A
| Wet/dry vacuum cleaner
|
1 Mark separation line (dotted line, 6) in center of front floor (1).
2 Mark separation lines (7, 19 and 20) with the following dimensions:
a = 490 mm,
b = 240 mm,
c = 90 mm measured from outer edge of cutout (arrow).
3 Expose spot welds in area (B) of front floor (1) and cut out.
4 Expose spot welds in area (C) of front floor (1) and grind.
5 Expose all spot welds of front floor (1) in shaded area up to separation lines (dotted lines 6, 7, 19 and 20) and cut out.
6 Mark separation line (8) along bracket (9) on front floor (1).
Cutting depth in area of cross braces (10), of reinforcement bracket (9) and along separation line (20) should be max. 1 mm.
7 Separate front floor (1) along separation lines (6, 7, 8, 19 and 20).
8 Expose spot welds on firewall in area (D) and cut out.