Toimintoryhmä 3 Kori, päällysrakenne › 61 Korin (päällysrakenteen) alaosa › 61.10 Pohjalevy — Mallisarja 690 (mallit 63*, 64*) · Mallisarja 901 (mallit 06*, 36*, 37*, 46*, 66*, 67*) · Mallisarja 902 (mallit 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Mallisarja 903 (mallit 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Mallisarja 904 (mallit 06*, 36*, 46*, 66*)

EinPAS 35 Kori/runko/liittyvät osat › 35.32 Alapohja › 35.32.35 Pohjarakenne/alustakehikko — Mallisarja 690 (mallit 63*, 64*) · Mallisarja 901 (mallit 06*, 36*, 37*, 46*, 66*, 67*) · Mallisarja 902 (mallit 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Mallisarja 903 (mallit 06*, 07*, 36*, 37*, 46*, 47*, 66*, 67*) · Mallisarja 904 (mallit 06*, 36*, 46*, 66*)

AR61.10-D-5720-01A

Separating front floor in cab up to firewall

Separating front floor in cab up to firewall

201 589 00 51 00

Spot weld miller

Commercially available tools

Number

Designation

WH58.30-Z-1004-20A

Hot-air gun

Workshop equipment

WE58.40-Z-1001-03A

Drill (electric/pneumatic)

WE58.40-Z-1003-03A

Angle grinder (electric/pneumatic)

WE58.40-Z-1004-03A

Body saw (electric/pneumatic)

WE58.40-Z-1005-03A

Wet/dry vacuum cleaner

Separating front floor in cab up to firewall
Separating front floor in cab up to firewall

D61.10-0064-03

D61.10-0063-03

1 Mark separation line (6) in center of front floor (1).

Cut spot welds out through cargo space floor and floor panel in one step.

2 Expose spot welds in area (A) up to behind separating line (6) and cut out.

Separating front floor in cab up to firewall

D61.10-0065-06

3 Expose spot welds in area (B) of front floor (1) and cut out.

4 Expose spot welds in area (C) of front floor (1) and grind down.

Separating front floor in cab up to firewall

5 Expose all spot welds of front floor (1) in shaded area up to separation line (6) and cut out.

D61.10-0066-03

Separating front floor in cab up to firewall

D61.10-0067-06

6 Mark separation line (8) along bracket (9) on front floor (1)

Cutting depth in area of lateral struts (10) and reinforcement bracket (9) max. 1 mm.

7 Separate front floor (1) along separation lines (6 8).

Separating front floor in cab up to firewall

D61.10-0086-01