ar1530p7100f

Remove/install starter

Tyyppi ar · aihe 15.30 · versio 0102 · 2012-02-16

Koskee: ENGINE 111.942 in MODEL 210.035 /235 ENGINE 111.970 in MODEL 210.037 /237 ENGINE 111.947 in MODEL 210.045 /245 ENGINE 104.945 in MODEL 210.053 ENGINE 104.995 in MODEL 210.055

Ei saatavilla kielellä ”fi”; näytetään kielellä Englanti.

Sijainti

Toimintoryhmä 1 Moottori › 15 Moottorin sähkölaitteet › 15.30 Käynnistinmoottori — Mallisarja 210 (mallit 035, 037, 045, 053, 055, 235, 237, 245)

EinPAS 15 Moottori › 15.35 Käynnistinmoottori › 15.35.20 Käynnistinmoottori — Mallisarja 210 (mallit 035, 037, 045, 053, 055, 235, 237, 245)

Koskee myös moottoreita/vaihteistoja: 104 945, 104 995, 111 942, 111 947, 111 970

AR15.30-P-7100F

Remove/install starter

15.2.12

ENGINE 111.942 in MODEL 210.035 /235

ENGINE 111.970 in MODEL 210.037 /237

ENGINE 111.947 in MODEL 210.045 /245

ENGINE 104.945 in MODEL 210.053

ENGINE 104.995 in MODEL 210.055

Remove/install starter

P15.30-2055-06

1 Electric line circuit 30

2 Electric cable circuit 50

3 Bolts

4 Bracket

M1 Starter

Remove/install

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

1

Disconnect battery ground line

Insulate cable lug of ground cable to provide protection from unintentional contact between disconnected ground cable and ground point W10

AR54.10-P-0003A

Notes on battery

All models

AH54.10-P-0001-01A

2

Detach lower engine compartment paneling

AR61.20-P-1105AB

3

Disconnect electric cables (1, 2)

Nut for connection circuit 30

*BA15.30-P-1001-01A

Nut for connection circuit 50

*BA15.30-P-1002-01A

4

Remove bracket (4)

5

Remove bolt (3)

Starter bolt

*BA15.30-P-1003-01A

6

Remove starter (M1) from below

7

Install in the reverse order

8

Carry out function check

9

Render electrical system operational

Carry out basic programming.

AR00.19-P-0200D

Starter

Number

Designation

Engine
103, 104, 111, 120

BA15.30-P-1001-01A

Nut, connection for circuit 30

Nm

14

BA15.30-P-1002-01A

Nut, connection for circuit 50

Nm

6

BA15.30-P-1003-01A

Bolt connecting starter to crankcase

Nm

42

Viitatut asiakirjat